Dehumidifier Size Calculator (Pints/Day)

Find the right dehumidifier capacity from room size and dampness using the AHAM sizing chart — with basement and ceiling corrections, cold-temperature guidance, DOE 2019 rating conversion, running-cost estimates, and two-room comparison. 100% in-browser.

Dehumidifier vs humidifier — which one do you need?

These two appliances do opposite jobs. A dehumidifier removes moisture — right for damp basements, humid summers, or any space where RH stays above 50%. If your air is too dry (RH below 30% in winter or dry climates) and you need to add moisture, you want the opposite appliance: use our humidifier size calculator.

Size your dehumidifier

Enter the room, pick how damp it feels, and get the AHAM pints/day plus the size printed on today's boxes (DOE 2019 rating).

Room A

Edit assumptions all editable

AHAM sizing chart (reference)

Pints of water removed per 24 hours. Capacities use the older 80°F / 60% RH test — see the DOE 2019 note in the results.

Dampness500 sq ft1,000 sq ft1,500 sq ft2,000 sq ft2,500 sq ft
Moderately damp1014182226
Very damp1217222732
Wet1420263238
Extremely wet1623303744
pints = base + add × (sqft ÷ 500 − 1), minimum = base
base/add: 10/4 · 12/5 · 14/6 · 16/7 — DOE 2019 pints ≈ AHAM pints × 50/70

Frequently asked questions

What size dehumidifier do I need for a 1,000 sq ft room?

It depends on dampness. For a very damp 1,000 sq ft room the AHAM chart gives 12 + 5 × (1000/500 − 1) = 17 pints per day, so you round up to the nearest retail size: a 20-pint unit (AHAM rating). That same unit is labeled about 14.3 pints under the DOE 2019 rating, which is the number printed on the box. A merely moderately damp room that size needs only 14 pints per day, still a 20-pint unit.

What is the AHAM dehumidifier sizing chart?

The Association of Home Appliance Manufacturers (AHAM) chart lists pints of water removed per 24 hours by room size and dampness. Per 500 sq ft the bases are: moderately damp 10, very damp 12, wet 14, extremely wet 16 pints. Add 4, 5, 6, or 7 pints respectively for each additional 500 sq ft. So a wet 1,500 sq ft space needs 14 + 6 × 2 = 26 pints per day. These pints use the older 80°F/60% RH test conditions.

Why do dehumidifiers sold today show smaller pint numbers than the AHAM chart?

In 2019 the DOE changed the rating test from 80°F/60% RH to 65°F/60% RH, and ENERGY STAR required new labels. Rated capacity fell about 29%: a unit rated 70 pints under the old test is sold as 50 pints under DOE 2019, a ratio of 50/70 ≈ 0.714. This calculator sizes in AHAM pints and converts, so the recommendation matches the number on the box.

How much does it cost to run a dehumidifier?

A typical 50-pint unit draws about 500 W. Running 8 hours a day at $0.17 per kWh uses 4.0 kWh per day, costing $0.68 per day — about $20.40 per month. Larger or older units draw more; the assumptions panel lets you enter your actual wattage, hours, and electricity rate.

Do I need a bigger dehumidifier for a basement or crawl space?

Yes. Basements and crawl spaces sit against cool earth and seep moisture, so add about 10% capacity (typical range 10–15%). Example: an 800 sq ft wet room needs 14 + 6 × (800/500 − 1) = 17.6 pints per day; as a basement that becomes 17.6 × 1.10 = 19.36 pints, rounded up to a 20-pint unit.

What if my basement is colder than 60°F?

Below about 60°F a standard compressor dehumidifier loses efficiency noticeably — choose a low-temperature auto-defrost model. Below about 50°F the coils ice up and a compressor unit removes almost nothing; use a desiccant or low-grain-refrigerant (LGR) dehumidifier rated for cold operation instead.

Does ceiling height change the dehumidifier size?

Yes, for ceilings above the 8 ft reference: scale capacity by ceiling height ÷ 8. Example: a 600 sq ft moderately damp room needs 10 + 4 × (600/500 − 1) = 10.8 pints per day; with a 10 ft ceiling that becomes 10.8 × 1.25 = 13.5 pints, so a 20-pint unit still covers it.

Can one dehumidifier cover two rooms?

Only if air moves freely between them (open plan, no closed doors). Otherwise each room needs its own sizing, because a closed door starves the second room of airflow. Use compare mode above: it sizes each room and also shows the single-unit size for the combined area at the worse dampness level.