nrtechstudio.com Tools Swamp Cooler Size Calculator

Swamp Cooler Size Calculator — What CFM Does Your Home Need?

Size an evaporative (swamp) cooler by CFM — not BTU. Seven calculators: whole-home CFM sizer, reverse CFM → square feet, single-room sizer, exhaust window opening, unit picker, climate suitability check, and the PG&E sizing chart. Built on the published PG&E / energy.gov sizing rules.

Choose a calculator

Add every room the cooler will serve. CFM = total volume ÷ 2 (30 air changes/hour), the standard published rule.

—
CFM needed (cubic feet per minute)
— m³/h — air changes/hour — ft³

Room breakdown

RoomDimensionsVolumeCFM share

Suggested unit

Buy this unit size
—
Open this much window exhaust
—

You already have (or are eyeing) a unit — how many square feet can it cover? Max sq ft = CFM ÷ 4 (hot, dry) or ÷ 3 (average), per PG&E.

—
sq ft covered in a hot, dry climate
— sq ft (average climate) — m²

Example: a 6,000 CFM unit covers up to 1,500 sq ft hot-dry or 2,000 sq ft average — exactly the PG&E table row.

One room, one number. CFM = room volume ÷ 2.

—
CFM for this room
—— air changes/hour

A swamp cooler pushes air in — the same amount must get out. Open windows/vents on the leeward side: 1–2 sq ft of opening per 1,000 CFM (energy.gov).

—
sq ft of window/vent opening
—— m²

Windows open too far → hot air floods in. Not open far enough → humidity builds up inside (energy.gov). Where open windows are a security issue, install ceiling up-ducts to exhaust warm air into the attic.

Know the CFM you need? Pick the unit. PG&E rule: between sizes → select the next larger cooler capacity.

—
unit to buy
—

Evaporative cooling only works in dry air. Check your summer climate before buying.

Typical July afternoon RH in your area.
Typical July afternoon high.

Why humidity matters: a swamp cooler cools by evaporating water into the air — and it adds moisture. In humid air there is little evaporation, so you get damp air with almost no cooling. Above ~60% RH, a refrigerated air conditioner is the honest answer.

The published PG&E sizing table for ducted evaporative coolers, with metric equivalents.

Cooler capacityAverage climateHot, dry climate

Table values: PG&E "Technical Sheet: Energy-Efficient Ducted Evaporative Coolers". Rule behind it: hot, dry = floor area × 4 CFM/sq ft (30 air changes/hour, 8-ft ceilings); average = floor area × 3 CFM/sq ft (22.5 air changes/hour).

How the math works

Two published rules that say the same thing:

CFM = room volume (ft³) ÷ 2 (= 30 air changes/hour) CFM = floor area (sq ft) × 4 (hot, dry — PG&E) CFM = floor area (sq ft) × 3 (average climate — PG&E)

At 8-ft ceilings both agree: 1,500 sq ft × 8 ft = 12,000 ft³ ÷ 2 = 6,000 CFM = 1,500 × 4. The ×4 shortcut only holds at 8-ft ceilings — with vaulted ceilings, use the volume formula.

Adjustments (+20%)

If any of these apply — ceilings above 8 ft, heavy sun exposure, or extra heat load (kitchen, servers, workshop) — add ~20% CFM (retailer sizing guidance, e.g. Sylvane). Example: 2,000 sq ft × 9-ft ceilings = 18,000 ft³ → 9,000 CFM base → 10,800 CFM adjusted.

Exhaust opening

A swamp cooler is a supply device: it pushes cooled air in, so the same volume must escape. energy.gov: open windows or vents on the leeward side to provide 1–2 sq ft of opening per 1,000 CFM. A 6,000 CFM unit needs 6–12 sq ft — for example three 2×2 ft windows (12 sq ft total).

Between sizes → go larger

PG&E: "When the floor area of your home is between sizes shown in the table, select the next larger cooler capacity." A slightly oversized evaporative cooler just moves more air; an undersized one never cools the house. Need 5,200 CFM → buy 5,500 CFM.

A wrong rule to ignore

Some AI-generated content claims "20–40 CFM per square foot." The math disproves it: 20 CFM/sq ft at 8-ft ceilings = 150 air changes/hour — five times what the largest residential units (~8,000 CFM) can deliver. The published numbers are 3–4 CFM per sq ft, not 20–40.

Worked examples

SpaceRuleResult
1,500 sq ft home, 8-ft ceilingsHot, dry: 12,000 ft³ ÷ 26,000 CFM
1,500 sq ft home, 8-ft ceilingsAverage climate: × 34,500 CFM
Bedroom 12 × 12 × 8 ft1,152 ft³ ÷ 2 (also 144 sq ft × 4)576 CFM
2,000 sq ft home, 9-ft ceilings18,000 ft³ ÷ 2, then +20%10,800 CFM
6,000 CFM unitExhaust: 1–2 sq ft per 1,000 CFM6–12 sq ft opening
Need 5,200 CFMNext-larger rule5,500 CFM unit
Need 10,800 CFMAbove the 6,500 max single unit2 × 5,500 CFM units

Examples computed with the same engine as the calculators above — change any input and re-run to verify.

Frequently asked questions

What size swamp cooler do I need for a 1,500 sq ft house?
For a 1,500 sq ft home with 8-ft ceilings (12,000 ft³ of air): in a hot, dry climate you need 6,000 CFM (12,000 ÷ 2, or 1,500 × 4 CFM per sq ft = 30 air changes per hour); in an average climate you need 4,500 CFM (1,500 × 3 CFM per sq ft = 22.5 air changes per hour). These are the PG&E published sizing formulas. Between standard unit sizes, PG&E says to pick the next larger cooler.
How many CFM per square foot does a swamp cooler need?
The published rule is 4 CFM per sq ft in hot, dry climates and 3 CFM per sq ft in average climates — both assume 8-ft ceilings (PG&E technical sheet: 30 and 22.5 air changes per hour respectively). If your ceilings are taller than 8 ft, use the volume formula instead: CFM = length × width × height ÷ 2.
What size swamp cooler for a 12×12 bedroom?
A 12 × 12 × 8 ft bedroom holds 1,152 ft³ of air, so it needs 1,152 ÷ 2 = 576 CFM. Both sizing methods converge on the same number here: 144 sq ft × 4 CFM per sq ft = 576 CFM. A small portable or window unit in the 500–800 CFM range covers it.
Do high ceilings change the swamp cooler size?
Yes. The 4-CFM-per-sq-ft shortcut assumes 8-ft ceilings, so with taller ceilings you must use the volume formula. Example: a 2,000 sq ft home with 9-ft ceilings holds 18,000 ft³ → 9,000 CFM base. Because the ceilings exceed 8 ft, add ~20% (retailer sizing guidance): 9,000 × 1.2 = 10,800 CFM — which means two units, since the largest standard single unit is 6,500 CFM.
How much window opening does a swamp cooler need?
Per energy.gov, open windows or vents on the leeward side of the house to provide 1–2 sq ft of opening per 1,000 CFM of cooling capacity. A 6,000 CFM unit therefore needs 6–12 sq ft of opening — for example three 2 × 2 ft windows (12 sq ft total). Too little opening and humidity builds up inside; too much and hot outside air floods in.
My calculation falls between unit sizes — which do I pick?
Pick the next larger size. PG&E's technical sheet is explicit: 'When the floor area of your home is between sizes shown in the table, select the next larger cooler capacity.' So if you need 5,200 CFM, buy the 5,500 CFM unit, not the 5,000. A slightly oversized evaporative cooler just moves more air; an undersized one never cools the house.
Will a swamp cooler work in my climate?
Evaporative coolers only work in dry air. As a screening rule: summer afternoon relative humidity at or below 40% with highs of 85°F or more is a good fit (the US Southwest); above ~60% RH they add dampness with almost no cooling — buy a refrigerated air conditioner instead. In hot, dry conditions, industry sources commonly cite temperature drops around 15°F; treat that as a planning estimate, not a guarantee, since actual results depend on humidity, airflow, and pad condition.
How is a swamp cooler different from a bathroom fan, AC, furnace, or dehumidifier?
Different physics, different tools: (1) A swamp cooler is a SUPPLY device — it pushes cooled air IN, measured in CFM. A bathroom exhaust fan (#2532) pushes stale air OUT — opposite airflow direction. (2) An air conditioner (#785) uses refrigerant and is sized in BTU/hr; CFM and BTU/hr are not interchangeable. (3) A furnace (#2530) is heating (BTU/hr) — the opposite season. (4) A dehumidifier (#2531) REMOVES moisture from air while a swamp cooler ADDS moisture — opposite humidity direction. Use this calculator only for evaporative cooling in dry climates.
Can I use two smaller swamp coolers instead of one big one?
Yes — that is the standard answer when your need exceeds the largest single residential unit (6,500 CFM). Example: a 10,800 CFM requirement is covered by two 5,500 CFM units (11,000 CFM total), typically one per zone of the house. Two units also give you redundancy and let you cool only the occupied zone.
Is the '20–40 CFM per square foot' rule true?
No — it is a myth from low-quality AI-generated content, and the math disproves it. 20 CFM per sq ft at 8-ft ceilings equals 150 air changes per hour, roughly five times what the largest residential units (about 8,000 CFM) can deliver. The published, checkable numbers are 3–4 CFM per sq ft (PG&E): a 1,500 sq ft home needs 6,000 CFM hot-dry or 4,500 CFM average — not 30,000–60,000.

Related tools

Boundary note — different tool, different physics: this calculator sizes an evaporative (swamp) cooler, a supply device measured in CFM that cools by evaporating water into dry air.
  • Bathroom fan CFM (#2532) sizes an exhaust fan that pushes stale air out of a bathroom — opposite airflow direction from a swamp cooler.
  • Air conditioner room size (#785) sizes refrigerant cooling in BTU/hr — different physics, not comparable to CFM.
  • Furnace size (#2530) is heating (BTU/hr), the opposite season.
  • Dehumidifier size (#2531) removes moisture from air; a swamp cooler adds moisture — opposite humidity direction.

Free tool by NRTechStudio