Furnace BTU sizer
Planning estimate only: design factor x sq ft, adjusted for insulation, ceiling height, and outdoor-boiler line loss. Have your dealer run a heat-loss calculation (Manual J) before buying.
Firebox size & annual wood use
1 cord = 128 cu ft stacked. A 23 cu ft firebox (Central Boiler Classic Edge 865 HDX spec) holds about 7.4 loads per cord at 75% fill.
Water capacity & circulation
Stored heat = gallons × 8.34 × ΔT. Flow: GPM = BTU/hr ÷ (500 × ΔT). Keep the circulator within its pump curve; insulated underground pipe is strongly recommended.
Cost: wood vs propane vs oil vs electric
Defaults use EIA residential prices from October 5, 2026 (propane $2.598/gal US average; heating oil $6.042/gal). Burner efficiencies: propane 92%, oil 85%. Adjust to your local prices.
Burn time / refuel interval
Assumes 75% firebox fill of stacked wood at 22 MMBTU per 128 cu ft cord. Real burn time varies with wood moisture, species, and weather.
BTU sizing table — sq ft × climate zone
Design heat load in kBTU/hr (average insulation, 8 ft ceilings, before line-loss adder). Imperial below; metric conversion under the table.
EPA emissions & setback guidance
Burn only clean, seasoned wood. Many localities add seasonal burn bans, fuel rules, and nuisance ordinances. Sources: EPA RIA for the 2015 NSPS revision; PA DEP; Allegheny County Health Dept.; municipal ordinances.
Frequently asked questions
What size outdoor wood furnace do I need for a 2,000 sq ft house?
As a planning estimate: multiply heated area by your climate-zone design factor (the 7-zone PickHVAC table: Zone 1 = 30 up to Zone 7 = 60 BTU/hr per sq ft). A 2,000 sq ft home in Zone 5 (50 BTU/hr per sq ft) needs about 100,000 BTU/hr of design heat load; add ~5% for underground line loss (105,000 BTU/hr) and round up to a 105,000 BTU/hr unit. Dealers also use a sizing value of 0.06 x sq ft: 2,000 x 0.06 = 120, which falls in the Central Boiler CL 4030 class (0-170 range). Confirm with a heat-loss calculation (Manual J) before buying.
How much firewood will an outdoor wood boiler burn per year?
Divide your annual delivered heat by wood energy and furnace efficiency. A 2,000 sq ft Zone 4 home needs about 235.6 MMBTU per year; at 65% furnace efficiency and 22 MMBTU per seasoned cord, that is about 16.5 cords per year. Real users report 8-12 cords for 2,500 sq ft in cold winters (e.g., a Central Boiler 6048 owner burning ~8 cords), and 10-20 cords in severe northern climates, depending on insulation and how much hot water is heated.
How often do I have to refill an outdoor wood furnace?
It depends on firebox size and heat load. One firebox load holds firebox volume x 0.75 fill x 171,875 BTU per stacked cubic ft (22 MMBTU per 128 cu ft cord) x efficiency. A 23 cu ft firebox (Central Boiler Classic Edge 865 HDX) holds about 1.93 MMBTU net per load at 65% efficiency: roughly 7.9 hours at its full 245,000 BTU/hr rating, or 16-24 hours at typical partial load. That firebox yields about 7.4 loads per cord.
Is an outdoor wood boiler worth it compared to propane or oil?
Wood usually wins on fuel cost per MMBTU. At EIA prices from October 5, 2026 (heating oil $6.042/gal, propane $2.598/gal US average), delivered heat costs about $51.51/MMBTU for oil, $30.86 for propane, $49.82 for electric resistance, versus about $17.48 for wood at $250/cord and 65% furnace efficiency. For 235.6 MMBTU/year that is roughly $4,120 for wood versus $12,137 for oil: about $8,018 saved per year, paying back a $12,000 installation in about 1.5 years.
Are outdoor wood boilers legal? What are the EPA rules in 2026?
New units must be EPA-certified under the NSPS for residential wood heaters (Subpart QQQQ, hydronic heaters). Step 1 (May 15, 2015) limited particulate emissions to 0.32 lb per MMBTU of heat output; Step 2 (May 15, 2020) tightened that to 0.10 lb/MMBTU (0.15 if tested with cordwood), roughly 3 times cleaner. Phase 2 white-tag models are over 80% cleaner than old uncontrolled units. Many states and towns add their own rules or outright bans, so check your local code before buying; this is general information, not legal advice.
How far from my house and property line must an outdoor wood furnace sit?
The EPA NSPS sets no federal setback; states and towns do, and they vary widely. Examples: Pennsylvania requires at least 50 ft from the property line with a stack at least 10 ft above the ground; Allegheny County PA requires 150 ft; Old Town, Maine requires 100 ft with operating months limited to October 15-April 15; Wawayanda, NY requires 100 ft setbacks on lots of 2+ acres and 25 ft from the structure being heated. Always verify your own municipality's ordinance; this is general information, not legal advice.
How much water does an outdoor wood boiler hold, and what pump do I need?
Stored heat equals gallons x 8.34 lb/gal x temperature swing in F. A 360-gallon unit (Central Boiler Classic Edge 865 HDX) with a 20F swing stores about 60,048 BTU. Circulator flow follows GPM = BTU/hr / (500 x delta-T in F): a 100,000 BTU/hr load at 20F delta-T needs 10 GPM, which calls for 1-1/4 in PEX or larger. Use insulated underground pipe; keep total head loss within your circulator's curve.
Can an outdoor wood furnace heat my domestic hot water too?
Yes, via a sidearm or plate heat exchanger on the water heater, and most owners do. Add about 25,000 BTU/hr of peak load to your sizing when including hot water (planning figure; actual peaks depend on simultaneous showers and laundry). Year-round hot-water-only operation typically adds 30,000-60,000 BTU per day, which is why many owners keep the furnace running through summer.
What happens if my outdoor wood furnace is oversized or undersized?
Oversized units idle and smolder, producing more smoke and creosote and wasting wood; undersized units cannot hold water temperature on the coldest nights and fall back on backup heat. Size to your design heat load with the underground line-loss adder, not to the biggest firebox you can afford, and have your dealer run a real heat-loss calculation. A slightly larger firebox is fine for longer burn times; a much larger rated output is not.
How is this different from an indoor furnace or boiler calculator?
This tool sizes OUTDOOR wood boilers/furnaces (hydronic heaters sited outside the building): it adds underground line loss, firebox burn-time math, wood-cord consumption, and EPA setback guidance. For an indoor forced-air furnace use our furnace size calculator; for an indoor hydronic boiler use our boiler size calculator; for pure firewood math (cord volume, species weight, seasoning) use our firewood stack calculator.