Heat Transfer Coefficient Calculator

Convert heat transfer coefficient units (W/m²·K ↔ BTU/(hr·ft²·°F) ↔ kcal/(h·m²·°C)), compute the U-value and R-value of multi-layer walls per ISO 6946, and estimate heat loss with Q = U·A·ΔT. Everything runs 100% in your browser — no data leaves your device.

—

Key factors: 1 BTU/(hr·ft²·°F) = 5.678263 W/m²·K · 1 kcal/(h·m²·°C) = 1.162992 W/m²·K · 1 W/(m²·°F) = 1.8 W/m²·K. R-value units convert inversely: 1 m²·K/W = 5.678263 hr·ft²·°F/BTU.

Build your wall from the inside out. Each layer contributes R = L/k (thickness ÷ thermal conductivity); surface film resistances 1/hin and 1/hout are added automatically.

— W/m²·K (U-value)

Defaults 8 / 23 W/m²·K follow DIN 4108 (simplified design values). EN ISO 6946 horizontal: Rsi = 0.13 (h ≈ 7.7) inside, Rse = 0.04 (h ≈ 25) outside. Change either value for roofs, floors or windy exposure.

Q = U × A × ΔT — heat flow (W) = U-value (W/m²·K) × area (m²) × temperature difference (K).
— W

Steady-state, one-dimensional conduction — ignores thermal bridges, air infiltration and solar gain. Example: U = 2.2, A = 20 m², ΔT = 20 K → 880 W.

Thermal conductivity table (k-values)

Representative thermal conductivity values used by the calculator. Real products vary — check manufacturer datasheets for certified values. Lower k = better insulator.

Materialk (W/m·K)Notes

U-value conversion reference

ConvertMultiply byExample
BTU/(hr·ft²·°F) → W/m²·K5.6782631 → 5.678 W/m²·K
W/m²·K → BTU/(hr·ft²·°F)0.1761102.20 → 0.387
kcal/(h·m²·°C) → W/m²·K1.1629921 → 1.163 W/m²·K
m²·K/W → hr·ft²·°F/BTU (R-value)5.6782630.454 → 2.58
W/(m²·°F) → W/m²·K1.81 → 1.8
cal/(s·cm²·°C) → W/m²·K418400.001 → 41.84

How the multi-layer U-value calculation works (ISO 6946)

1/U = 1/hin + Σ (Li / ki) + 1/hout
  1. Layer resistance: each solid layer resists heat flow in proportion to its thickness and inversely to its conductivity: Ri = Li/ki (m²·K/W).
  2. Surface resistances: the air films on the inside and outside faces add Rsi = 1/hin and Rse = 1/hout. For walls (horizontal heat flow) ISO 6946 uses 0.13 inside and 0.04 m²·K/W outside; common simplified design practice (DIN 4108) uses hin = 8 and hout = 23 W/m²·K — the defaults here.
  3. Total and U-value: Rtotal = Rsi + ΣRi + Rse; the U-value (thermal transmittance) is U = 1/Rtotal in W/m²·K.

Typical U-values (W/m²·K)

ConstructionU (W/m²·K)Rating
Passive-house wall< 0.15Excellent
Modern well-insulated wall0.15 – 0.30Excellent
Typical new construction0.30 – 0.45Good
Older building, thin insulation0.80 – 2.00Poor
Bare 200 mm brick wall≈ 2.20Very poor
Single glazing window≈ 5.8Very poor

Scope boundary

This tool covers the overall heat transfer coefficient (U-value) and its units, the R-value of wall assemblies, and steady-state heat loss Q = U·A·ΔT. It is not an insulation-product database (no brands, prices or R-per-inch buying guides), not a window-frame/door calculator, and not a heat-exchanger sizing tool with fouling factors — those belong to dedicated tools.

Related: browse all nrtechstudio.com tools.

Frequently asked questions

What is the overall heat transfer coefficient (U-value)?
The overall heat transfer coefficient, usually called the U-value or thermal transmittance, measures how much heat passes through a building element or heat exchanger per square metre for each degree of temperature difference. It is expressed in W/m²·K (SI) or BTU/(hr·ft²·°F) (imperial). A lower U-value means less heat escapes, i.e. better insulation; a higher value means more heat transfer.
How do you calculate the U-value of a multi-layer wall?
Add the thermal resistances in series: Rtotal = 1/hin + Σ(Li/ki) + 1/hout, where Li is the thickness and ki the thermal conductivity of each layer, and hin/hout are the interior and exterior surface film coefficients. Then U = 1/Rtotal. This calculator does it for you: pick materials, enter thicknesses, and it sums every layer resistance plus the standard surface resistances.
What is the difference between U-value and R-value?
R-value (thermal resistance, m²·K/W) measures how strongly a material or assembly resists heat flow, so higher is better. U-value (thermal transmittance, W/m²·K) measures how easily heat passes, so lower is better. They are reciprocals: U = 1/R. R-values of layers add up in series, so insulation is usually quoted in R, while whole walls, windows and roofs are quoted in U.
How do I convert W/m²·K to BTU/(hr·ft²·°F)?
Divide by 5.678263. For example, a wall with U = 2.20 W/m²·K equals 2.20 / 5.678263 ≈ 0.387 BTU/(hr·ft²·°F). Conversely, multiply the imperial value by 5.678263 to get W/m²·K.
How do I convert BTU/(hr·ft²·°F) to W/m²·K?
Multiply by 5.678263. For example, 1 BTU/(hr·ft²·°F) = 5.678263 W/m²·K. The conversion factor comes from the definitions of the BTU, the foot and the Fahrenheit degree: 1 BTU/(hr·ft²·°F) = 1055.06 J ÷ (3600 s × 0.092903 m² × 5/9 K) = 5.678263 W/m²·K.
What are standard interior and exterior surface film coefficients?
For walls with horizontal heat flow, EN ISO 6946 gives surface resistances Rsi = 0.13 m²·K/W inside (h ≈ 7.7 W/m²·K) and Rse = 0.04 m²·K/W outside (h ≈ 25 W/m²·K). Common simplified design values are hin = 8 and hout = 23 W/m²·K (DIN 4108). This calculator defaults to 8/23 and lets you change both.
What is thermal conductivity (k-value)?
Thermal conductivity (λ or k, in W/m·K) is a material property telling how easily heat conducts through it: copper (~385) and steel (~50) conduct fast, while insulation like glass wool (~0.040) and polyurethane foam (~0.023) conducts very slowly. A layer resistance is its thickness divided by k (R = L/k), so thicker layers and lower k give higher resistance.
How do you calculate heat loss through a wall?
Q = U × A × ΔT, where U is the overall heat transfer coefficient (W/m²·K), A the wall area (m²) and ΔT the inside-outside temperature difference in kelvin (same as °C). Example: U = 2.2, A = 20 m², ΔT = 20 K → Q = 880 W. Use Mode 3 above and it converts areas, units and temperature scales for you.
What is a good U-value for walls?
Passive-house walls target below 0.15 W/m²·K. Modern well-insulated walls reach 0.15–0.30, typical new construction 0.30–0.45, older buildings 0.80–2.00. A bare 200 mm clay-brick wall is about 2.2 W/m²·K — poor. Most building codes now set maximum U-values, so check your local requirement.
How do I convert R-value from SI to imperial?
Multiply the SI R-value (m²·K/W) by 5.678263 to get the imperial R-value (hr·ft²·°F/BTU). For example, R = 0.454 m²·K/W becomes about 2.58 hr·ft²·°F/BTU. It is the same factor as the U conversion, applied the other way around.
What is the formula for the overall heat transfer coefficient?
1/U = 1/hin + Σ(Li/ki) + 1/hout. The left side is the total resistance; on the right, 1/hin and 1/hout are the interior/exterior surface (film) resistances and Li/ki is the resistance of each solid layer. Invert the total resistance to get U. For a single surface, the local heat transfer coefficient is simply h = 1/Rsurface.
What U-value does a passive house need?
Passive House Institute criteria require opaque envelope components (walls, roof, floor) to achieve U ≤ 0.15 W/m²·K (≤ 0.026 BTU/(hr·ft²·°F)). Windows must reach U ≤ 0.80 W/m²·K including the frame. Reaching these values typically needs 200–300 mm of mineral wool or equivalent.
Is a lower U-value always better?
For insulation, yes — a lower U-value means less heat escapes, cutting heating and cooling bills. But material choice also weighs cost, thickness, moisture behaviour, fire rating and embodied carbon. For heat exchangers the opposite holds: a higher overall heat transfer coefficient means more efficient heat transfer.
What is the U-value of a 200 mm brick wall?
With standard surface coefficients (hin = 8, hout = 23 W/m²·K): R = 1/8 + 0.2/0.7 + 1/23 = 0.125 + 0.2857 + 0.0435 = 0.4542 m²·K/W, so U = 1/0.4542 ≈ 2.20 W/m²·K (≈ 0.388 BTU/(hr·ft²·°F)). Adding 50 mm of glass wool (k = 0.040) drops it to about 0.62 W/m²·K — try the preset above.

Free tool by NRTechStudio