Damping Ratio (ζ) Calculator
Compute the damping ratio ζ = c / (2·√(k·m)) with its classification (under / critical / overdamped), damped frequency, logarithmic decrement, and percent overshoot. Also works in reverse: find the damper coefficient c from a target ζ, or ζ from a measured δ.
Scope limits
This tool computes the ratio ζ = c/cc with its classification and derived quantities (ωd, δ, overshoot). If what you need is the critical damping coefficient cc itself (cc from m & k, or finding k/m from cc), use the dedicated critical-damping tool — here cc is shown only as comparative info, not as a solver mode.
- Critical damping cc (info)
- – N·s/m
- ωn (natural)
- – rad/s
- fn
- – Hz
- ωd (damped)
- – rad/s
- fd
- – Hz
- Log decrement δ
- –
- Percent overshoot
- – %
- Critical damping cc (info)
- – N·s/m
Formulas used
Verified example: c = 4 N·s/m, m = 1 kg, k = 100 N/m → ζ = 4/(2·10) = 0.2 (underdamped); ωn = 10 rad/s; ωd ≈ 9.79796 rad/s; δ ≈ 1.28254983; PO ≈ 52.66%. Design: target ζ = 0.5 with m = 1 kg, k = 100 N/m → c = 10 N·s/m. Conversion: 50 lbf/in = 8756.34176 N/m; 2 lb = 0.90718474 kg.
Frequently asked questions
What is the damping ratio (ζ)?
The damping ratio ζ is a dimensionless number measuring how strongly a mass–spring–damper system is damped relative to critical damping: ζ = c / c_c = c / (2·√(k·m)), where c is the damping coefficient [N·s/m], m the mass [kg], and k the spring stiffness [N/m]. ζ = 0 means no damping (it vibrates forever); the larger ζ, the faster oscillations die out.
How are underdamped, critically damped, and overdamped classified?
ζ < 1 = underdamped (vibrates with decaying amplitude); ζ = 1 = critically damped (returns to equilibrium fastest without oscillation); ζ > 1 = overdamped (returns slowly without oscillation). Example: c = 4, m = 1 kg, k = 100 N/m gives ζ = 4/(2·10) = 0.2 (underdamped); c = 20 gives ζ = 1 exactly (critical); c = 40 gives ζ = 2 (overdamped).
How is ζ related to the natural and damped frequencies?
The natural frequency is ω_n = √(k/m). For an underdamped system (ζ < 1), the damped frequency is ω_d = ω_n·√(1−ζ²) — always slightly below ω_n. Anchor example: k = 100 N/m, m = 1 kg → ω_n = 10 rad/s (f_n ≈ 1.59155 Hz); with ζ = 0.2 → ω_d = 10·√0.96 ≈ 9.79796 rad/s (f_d ≈ 1.55939 Hz). For ζ ≥ 1, ω_d is undefined because there is no oscillation.
What is the logarithmic decrement and how do I compute ζ from it?
The logarithmic decrement δ = ln(x_n/x_{n+1}) measures the decay rate between two successive peaks, and δ = 2πζ/√(1−ζ²) for ζ < 1. The inverse formula is ζ = δ/√(4π²+δ²). Anchor example: ζ = 0.2 → δ = 2π·0.2/√0.96 ≈ 1.28254983; conversely a measured δ = 1.28254983 → ζ = 0.2.
What is the percent overshoot for a given ζ?
For the step response of an underdamped second-order system, percent overshoot PO = 100·e^(−πζ/√(1−ζ²)) percent. Example: ζ = 0.2 → PO ≈ 52.66%; ζ = 0.5 → PO ≈ 16.30%. PO is only meaningful for ζ < 1; at ζ ≥ 1 there is no overshoot.
How do I design a damper for a target ζ?
Invert the formula: c = ζ·2·√(k·m). Example: target ζ = 0.5 with m = 1 kg and k = 100 N/m → c = 0.5·2·10 = 10 N·s/m. This calculator reports the critical damping value c_c = 2·√(k·m) for comparison — a dedicated c_c solver (from m & k, or the inverse) is available in the critical-damping tool.
Which units are supported?
Mass: kg, g, lb (1 lb = 0.45359237 kg). Spring stiffness: N/m, N/mm, lbf/in (1 lbf/in = 175.126835246476 N/m; example 50 lbf/in = 8756.34176 N/m). The damping coefficient c is always in N·s/m (SI). All calculations are converted to SI first, then results are shown in SI units.
How does this tool differ from the critical-damping calculator?
This tool computes the RATIO ζ = c/c_c plus classification (under/critical/over), damped frequency, logarithmic decrement, and percent overshoot. The critical-damping tool (#1571) focuses on the critical damping coefficient c_c itself as the sought quantity (c_c from m & k, or k/m from c_c). The two complement each other: here c_c is only intermediate info, not a solver mode.
When do the results of this calculator not apply?
These formulas apply to linear viscous damping on a single-degree-of-freedom system. Coulomb damping (dry friction), structural/hysteresis damping, or non-linear systems use different models. δ, ζ-from-δ, and PO are only defined for ζ < 1 (oscillation present); ζ ≥ 1 input in those modes will be rejected with a clear message.
Related tools
- Critical Damping Calculator — compute the critical damping coefficient cc itself from m & k (or vice versa).
- Spring Rate Converter — convert & compute spring stiffness k (N/mm, N/m, lbf/in) + series/parallel.
- Weight to Mass Converter — convert weight to mass (kg, g, lb) for input m.
Free tool by NRTechStudio