What size ceiling fan for your room? Pick the right blade span from the university sizing table, solve the downrod for your ceiling height, check clearances, grade CFM/W efficiency, and estimate air-conditioning savings — all in one free tool.
Blade-span tiers follow Virginia Tech Extension BSE-290, Table 1 (Room size and suggested fan diameter) exactly. Rooms of exactly 75 / 144 / 225 / 400 sq ft sit on a boundary between two tiers — the tool shows both honestly.
| Room area | Suggested blade span |
|---|---|
| Up to 75 sq ft | 29–36" |
| 76–144 sq ft | 36–42" |
| 144–225 sq ft | 44" |
| 225–400 sq ft | 50–54" |
| Over 400 sq ft | Off table — see Multi-Fan Planner |
Flush-mount suits ceilings around 8 ft, standard mounts suit ~9 ft, and ceilings over 10 ft need an extended downrod (Hunter Fan). The target is blades 8–9 ft above the floor; the code minimum is 7 ft.
Rooms over 400 sq ft fall off the sizing table, and DOE guidance notes that rooms longer than 18 ft do better with multiple fans. This mode plans fan count, spacing, and the maximum blade span that keeps 18" of clearance from every wall.
Enter the fan's rated high-speed airflow (CFM) and power (watts) to get its CFM/W. The grade is measured against real published bars — never invented numbers.
DOE-cited guidance (UF IFAS): raising the thermostat about 2°F with a fan running cuts cooling costs 4–6% with no comfort loss. The tool uses the 5% midpoint and subtracts the fan's own running cost.
Three hard rules: blades at least 7 ft above the floor (code minimum), at least 18" from any wall, and at least 8" below the ceiling (DOE via UF IFAS).
Pick where the fan goes and get the UL rating it needs (Hunter Fan / BSE-290). Indoor dry-rated fans must never be installed outdoors.
A ceiling fan circulates air inside a room — it has no ducting, removes no moisture, and produces no heat or cold. These sibling tools cover the neighbors:
Exhaust fan that removes moisture out of the bathroom (HVI 1 CFM/sq ft). A damp-rated ceiling fan in a bathroom is not an exhaust fan — you may need both.
AC actually lowers temperature and humidity (BTU cooling load). A ceiling fan only makes occupants feel ~4°F cooler via wind chill.
Heating load in BTU. A ceiling fan produces no heat; its winter mode only redistributes warm air already in the room.
Also distinct: range-hood CFM (kitchen grease/smoke exhaust through ducting), swamp-cooler size (evaporative supply air that adds moisture), and dehumidifier size (removes moisture from the air) — none of which a ceiling fan does.
Free tool by NRTechStudio
Explore similar home improvement tools and calculators. 100% free, accurate, and runs completely in your browser without sign-up.