HOMA-IR Calculator
Estimate insulin resistance from two fasting blood values — fasting insulin and fasting glucose — using the Homeostatic Model Assessment (Matthews et al., 1985), plus the QUICKI insulin-sensitivity index (Katz et al., 2000), HOMA-β beta-cell function, and automatic unit conversion. Free, private, 100% in your browser.
⚕️ Educational — not medical advice. Insulin resistance assessment needs clinical context.
Calculate your HOMA-IR
Enter the two values from the same fasting blood draw (at least 8 hours without food). Pick the units printed on your lab report — conversion is automatic.
Your results
Show your work
Interpretation ranges
Cutoffs vary by population and assay — these are commonly cited values (a cutoff of ≥2.5 is used by NHANES; values between 2.0 and 3.0 are commonly used in clinical and research settings; some Asian cohorts use lower cutoffs around 1.4–2.5).
HOMA-IR
| Range | Commonly cited meaning |
|---|---|
| < 1.0 | Optimal insulin sensitivity |
| 1.0 – 2.5 | Normal range |
| > 2.5 | Suggests insulin resistance — discuss with a clinician |
QUICKI (higher is better — opposite direction from HOMA-IR)
| Range | Commonly cited meaning |
|---|---|
| ≥ 0.357 | Suggests normal insulin sensitivity |
| 0.339 – 0.356 | Borderline |
| < 0.339 | Suggests insulin resistance — discuss with a clinician |
Worked example
Fasting insulin 10 µU/mL, fasting glucose 90 mg/dL:
Notice the two indices can disagree near cutoffs — HOMA-IR 2.22 reads "normal" while QUICKI 0.338 reads just below its threshold. Borderline disagreement is a sign to look at the full clinical picture, not one number.
What each component means
Fasting insulin (µU/mL or pmol/L)
How much insulin your pancreas releases to hold glucose steady after an overnight fast. When cells resist insulin's signal, the pancreas compensates by releasing more — so a higher fasting insulin pushes HOMA-IR up. Divide pmol/L by 6.945 to get µU/mL.
Fasting glucose (mg/dL or mmol/L)
Your blood sugar after at least 8 hours without food. Even "normal" glucose maintained by very high insulin still raises HOMA-IR — that is the point of the index: it sees the effort, not just the result. Divide mg/dL by 18 to get mmol/L.
Why 22.5 (or 405)?
The constant normalizes the index so that a typical healthy young adult scores about 1.0. It comes from the original Matthews et al. calibration: with glucose in mmol/L the divisor is 22.5; with glucose in mg/dL it is 405 (22.5 × 18).
Why must the values be fasting?
After a meal, glucose and insulin swing wildly for hours. The model assumes a steady basal state, which only an 8+ hour fast approximates. Non-fasting values make the result meaningless.
HOMA-IR vs QUICKI
| HOMA-IR | QUICKI | |
|---|---|---|
| Published | Matthews et al., 1985 | Katz et al., 2000 |
| Measures | Insulin resistance (higher = worse) | Insulin sensitivity (higher = better) |
| Formula | (insulin × glucose) ÷ 22.5 | 1 ÷ (log10(insulin) + log10(glucose)) |
| Commonly cited cutoff | > 2.5 suggests resistance | < 0.339 suggests resistance |
| Strength | Most widely cited; familiar threshold | Log transform is more linear; correlates slightly better with clamp studies |
This calculator reports both from the same inputs, so you can compare them directly.
Quick unit converter
Frequently asked questions
What is HOMA-IR?
HOMA-IR (Homeostatic Model Assessment for Insulin Resistance) is a mathematical model published by Matthews et al. in 1985 that estimates insulin resistance from two routine fasting blood values: fasting insulin and fasting glucose. When cells respond poorly to insulin, the pancreas releases more of it to keep glucose steady, so the product of the two values rises. HOMA-IR captures that relationship in a single number. It is an estimate, not a diagnosis — insulin resistance assessment needs clinical context.
How is HOMA-IR calculated?
HOMA-IR = (fasting insulin in µU/mL × fasting glucose in mmol/L) ÷ 22.5. If your glucose is reported in mg/dL, use HOMA-IR = (fasting insulin in µU/mL × fasting glucose in mg/dL) ÷ 405, or first convert glucose to mmol/L by dividing by 18. Both inputs must come from the same fasting blood draw, taken after at least 8 hours without food.
What is a normal HOMA-IR range?
Commonly cited ranges — cutoffs vary by population and assay — are: below 1.0 optimal insulin sensitivity; 1.0 to 2.5 the normal range; above 2.5 suggesting insulin resistance. A cutoff of 2.5 or higher is widely used (NHANES uses ≥2.5), and values between 2.0 and 3.0 are commonly used in clinical and research settings. Some populations, for example several Asian cohorts, use lower cutoffs around 1.4–2.5. Treat any single number as a screening signal, not a verdict — trends over time in the same person are usually more informative.
What does a HOMA-IR above 2.5 suggest?
A HOMA-IR above 2.5 is the commonly cited threshold suggesting insulin resistance — meaning the body may need more insulin than usual to keep fasting glucose steady. It does not diagnose insulin resistance, prediabetes, or diabetes on its own. Clinicians interpret it alongside fasting glucose, HbA1c, lipids, blood pressure, weight history, and medications before drawing conclusions.
What is QUICKI?
QUICKI (Quantitative Insulin Sensitivity Check Index) was proposed by Katz et al. in 2000 as a log-transformed companion to HOMA-IR. It is calculated as QUICKI = 1 ÷ (log10(fasting insulin in µU/mL) + log10(fasting glucose in mg/dL)). Because it measures insulin sensitivity rather than resistance, higher QUICKI values are better — the opposite direction from HOMA-IR.
What is a normal QUICKI value?
Commonly cited QUICKI ranges are: 0.357 and above suggesting normal insulin sensitivity; 0.339 to 0.356 borderline; below 0.339 suggesting insulin resistance. These thresholds come from validation studies against glucose-clamp measurements and vary across populations, so use them as orientation, not as a diagnosis.
HOMA-IR vs QUICKI: which should I look at?
They are two views of the same fasting numbers. HOMA-IR is more widely cited and its 2.5 threshold is familiar in clinical practice; QUICKI's log transform makes it more linear across the range and it correlates slightly better with clamp-measured sensitivity in validation studies. This calculator shows both so you can compare — agreement between them strengthens the signal, and the FAQ below explains what disagreement means.
Why do my HOMA-IR and QUICKI seem to disagree?
It happens near the cutoffs. For example, fasting insulin 10 µU/mL with glucose 5.0 mmol/L (90 mg/dL) gives HOMA-IR 2.22 — inside the normal range — but QUICKI 0.338, just under the 0.339 threshold that suggests insulin resistance. The two indices use different math and different published cutoffs, so borderline values can land on opposite sides. When they disagree, neither overrules the other — it is a sign to look at the full clinical picture rather than one number.
How do I convert glucose from mg/dL to mmol/L?
Divide mg/dL by 18 to get mmol/L; multiply mmol/L by 18 to go back. For example, 90 mg/dL ÷ 18 = 5.0 mmol/L. This calculator converts automatically — just pick the unit printed on your lab report.
How do I convert insulin from pmol/L to µU/mL?
Divide pmol/L by 6.945 to get µU/mL (equivalently, 1 µU/mL = 6.945 pmol/L). For example, 69.45 pmol/L ÷ 6.945 = 10 µU/mL. Select pmol/L in the insulin unit dropdown and the calculator handles the conversion.
What is HOMA-β?
HOMA-β (beta-cell function) comes from the same Matthews et al. 1985 paper as HOMA-IR and estimates how hard the pancreatic beta cells are working: HOMA-β = (20 × fasting insulin in µU/mL) ÷ (fasting glucose in mmol/L − 3.5), expressed as a percentage of normal. Values around 100% suggest typical beta-cell function for the glucose level; it is undefined when fasting glucose is 3.5 mmol/L or lower. Like HOMA-IR, it is an estimate that needs clinical context.
Can HOMA-IR diagnose insulin resistance or diabetes?
No. HOMA-IR is a screening estimate, not a diagnostic test. It is unreliable in people with diagnosed diabetes, people using insulin or glucose-lowering medication, during acute illness or stress, and in some groups such as lean or elderly individuals. A high value suggests further evaluation; a normal value does not rule out metabolic problems. This tool is educational — not medical advice — and any concerning result should be discussed with a clinician.
Sources: Matthews DR et al., "Homeostasis model assessment: insulin resistance and β-cell function from fasting plasma glucose and insulin concentrations in man," Diabetologia 1985; Katz A et al., "Quantitative insulin sensitivity check index: a simple, accurate method for assessing insulin sensitivity in humans," J Clin Endocrinol Metab 2000; HOMA-IR cutoff ≥2.5 per NHANES; commonly used 2.0–3.0 range per MDCalc HOMA-IR review.